Extraction Procedure Details
The indication for each type of lead extraction across the TV was
recorded. Indications were divided into broad categories: 1) infection
(bacteremia, endocarditis, lead vegetation and/or pocket infection); 2)
lead dysfunction (lead failure, dislodgement, recall, perforation or
elevated capture threshold); 3) device upgrade (leads extracted either
due to ipsilateral venous occlusion or to avoid redundant hardware); 4)
TR as primary indication for TLE; and 5) other indications. All patients
underwent lead extraction in either the electrophysiology lab or a
hybrid operating room. Cardiothoracic surgical back-up and perfusion
teams were available in selected cases based on institutional protocol,
typically for lead dwell time > 5 years or if felt to be
high-risk for complications based on operator discretion.
The technical aspects of the lead extraction procedure were at operator
discretion. Typically, leads which could not be removed with simple
traction were prepped with locking stylets. The use of powered sheaths
typically included the GlideLight Laser sheath (Spectranetics/Phillips,
Colorado Springs, Colorado) or for mechanically-powered sheaths, either
the TightRail Rotating Dilator Sheath (Spectranetics/Phillips) or the
Cook Evolution RL (Cook Medical, Bloomington, IN). For the purposes of
this study, the use of extraction tools was subdivided into
laser-powered, mechanical-powered or a combination of both when multiple
forms of powered sheaths were used. Femoral extraction tools were used
when needed, at operator discretion.
Echocardiographic Assessment :
Severity of TR was assigned a grade of 0 to 3 (0=none/trivial TR, 1=mild
TR, 2=moderate TR, 3=severe TR). For patients whose TR was reported as a
range (i.e. mild to moderate), the less severe TR grade was recorded.
Change in TR after TLE was considered clinically significant if the
change was > 1 grade on the 0-3 scale.
Data Analysis :
Statistical analysis was performed using SPSS software (IBM, Armonk,
NY). Categorical variables are given as numbers (percentages) and
continuous variables are presented as means. Chi-square analysis was
performed to compare changes in baseline clinical characteristics and
extraction methods. A two-sample t-test was used to compare means
between the two groups. A p value of < 0.05 was considered
significant.
Results :
Patient Characteristics :
Out of 1813 patients who underwent TLE during the study period, 321
patients (17.7%) with echocardiograms before and after extraction were
included in this analysis. Clinical characteristics of the study cohort
are listed in Table 1.
A total of 338 leads were extracted across the TV (1.05 ± 0.31 leads
across the TV per patient; Table 1). The RV leads extracted included 121
pacing leads (37.7%) and 200 defibrillator leads (62.3%). Indications
for TLE included infection (n=186, 57.9%; 12 patients had evidence of
TV endocarditis), lead dysfunction (n=65, 20.2%), device upgrade (n=58,
18.1%; 13 of these were extracted due to ipsilateral vein occlusion),
TR (n=6, 1.9%) and other (n=6, 1.9%) (Table 1). There were no
immediate procedural complications from RV lead extraction.
Changes in Tricuspid Regurgitation after Lead Extraction :
The average time between baseline echocardiogram and TLE was 80.7 ±
174.8 days, and the average time between TLE and follow-up
echocardiogram was 78.3 ± 113.3 days. Of the 321 patients, 153 patients
(47.7%) did not have any change in TR grade following lead extraction,
while 84 patients (26.2%) had an improvement in TR grade following lead
extraction (Fig. 1, 2). Worsening TR following lead extraction was
observed in 84 patients (26.2%) (Fig. 1, 2). Overall, there was no
significant difference in average TR grade pre- and post-extraction
(1.18 ± 0.91 vs. 1.15 ± 0.87; p=0.79; Fig. 1).
Patients were stratified by those who developed worsening TR
post-extraction (n=84, 26.2%) and those whose TR either stayed the same
or improved post extraction (n=237, 73.8%). There was no difference in
baseline clinical characteristics, type (pacing vs. ICD lead) or number
of leads extracted, or indication for extraction between the two groups
(Table 1). Endocarditis with involvement of the TV did not significantly
influence the change in TR post-extraction (Table 1).
Only 8 patients (2.5%) had significant worsening of TR (>
1 grade): 4 patients had TR increase from mild to severe
post-extraction, and the other 4 had an increase from none/trivial at
baseline to moderate TR post-extraction (Fig. 2, Table 3). Improvement
in TR was observed in 84 patients, of whom 16 patients had significant
improvement in TR: 10 patients had TR decrease from moderate to
none/trivial post-extraction, and 6 had TR decrease from severe to mild
post-extraction (Fig. 2, Table 3). There was no difference in mean dwell
time of leads between patients in whom TR worsened post-extraction
compared to those in whom TR stayed the same or improved post-extraction
(6.9 years ± 13.1 years vs. 6.0 years ± 11.2 years, p=0.55; Table 2).
Powered extraction sheaths were used in 202 procedures (81 mechanical,
78 laser, 34 combination of mechanical and laser; Table 2). The use of
extraction tools was associated with a numerically higher rate of
worsening TR compared to extraction with simple traction, although this
difference was not significant (70.2% vs. 60.3%, p=0.11; Table 2). The
use of laser lead extraction (laser or combination) was associated with
a higher rate of worsening TR post-extraction (44.0% vs. 31.6%,
p=0.04) compared to mechanical extractions (25.0% vs. 25.3%, p=0.95)
(Table 2). Of note, extractions that required laser-powered sheaths had
longer average lead dwell times (10.1 ± 15.1 years vs. 4.2 ± 8.9 years;
p<0.01; Fig. 3).
Discussion :
In this large cohort of patients undergoing TLE, we found that the risk
of significant worsening TR after lead extraction is low (2.5%). In
addition, we found that most patients (73.8%) had unchanged TR or
improved TR after lead extraction.
TLE remains an important procedure in the management of CIED-related
problems.7 While the overall major complication rate
of TLE remains low at 0.2-3.4%,3 damage to the TV
during lead extraction remains a concern. Increased TR after lead
extraction has been reported to occur in 3.5-15% of
cases.8-10 Variation in reported TR after lead
extraction could be related to the definition of TR, extraction methods
or timing of imaging. For instance, Park et al9reported that significant acute TR occurred in 11.5% of their cohort,
with one requiring emergency TV replacement. A significant TR increase
was defined as an increase of at least 1 grade. In addition, evaluation
of valvular function pre and post extraction was performed via
intra-procedural transesophageal echocardiogram (TEE) in all cases.
Administration of general anesthesia, volume status, and RV function
during the procedure can affect the assessment of TR and may not
accurately affect long-term TV function.11 By
comparison, Polewczyk et al12 conducted a multi-center
post hoc analysis of 2631 patients and found that in 90.31% of
procedures, TLE had no negative influence on TV function. A significant
increase in TR was defined by 2 grades or more, similar to our study.
While risk factors for TLE-related TV damage (TVD) have not been clearly
identified, various risk factors have been proposed for TVD following
lead extraction. These include both younger10, 12 and
older patient age,8 higher left ventricular ejection
fraction,12 extraction of pacemaker rather than
defibrillator leads,9 removal of ≥ 2 leads and female
sex13. In our cohort, we did not identify any
significant differences in patient or procedural characteristics between
those with worsened TR after TLE compared to those with unchanged or
improved TR.
Longer dwell time is associated with the development of scar tissue,
fibrosis and calcification encapsulating intravascular leads and thus
often necessitates the use of powered sheaths.14Similarly, long dwell time is also associated with more fibrosis and
scar tissue around the lead and the leaflet. Therefore, excessive
traction on the lead during TLE could result in flail leaflets and
worsening TR.
Several studies showed that a longer dwell time prior to TLE
corresponded to a higher rate of TLE-related TR.9, 12While our study did not show any association between average dwell time
and TLE-related TR, the use of laser-powered sheaths, which was
associated with longer dwell time, was associated with worsened TR.
Our study has several limitations. Importantly, we only included
patients with echocardiograms before and after lead extraction, which
resulted in inclusion of only a minority of patients undergoing TLE.
While this certainly has the potential to introduce selection bias, it
is likely that patients in whom there is greatest clinical concern for
tricuspid valve dysfunction or right heart failure would be most likely
to have echocardiograms performed. Additionally, we included patients
with an echocardiogram performed up to one year following TLE to assess
for change in TR. Acute peri-procedural changes may have resolved by the
time the echocardiogram was performed. However, in contrast to prior
studies which have assessed change in TR solely based on
intra-procedural TEE before and after extraction, our data likely
provide a better assessment of long-term TR beyond the impact of acute
procedural loading conditions.
Conclusion :
In our single-center analysis, extraction of leads across the TV did not
significantly alter the extent of TR. Laser lead extraction was
associated with a higher rate of worsening TR after extraction, although
this may be the result of a longer dwell time for the leads requiring
laser-powered sheaths. Further studies are needed to determine if
certain TLE strategies predispose to worsening TR.